AL Small-size Air Filter
DSF-AL/ LSF-AL/ MSF-AL/ KSF-AL Series
High performing air filter adopting an element manufactured in Japan.
DSF, LSF, MSF, KSF, 75-AL~2000-AL
Air processing capacity
0.35~20 m3/min
Inlet air temperature
5~60℃

Special Features
Adopts a high performing element manufactured in Japan
- Super drain filter DSF series 〔Removes water vapour and solid substance (above 5μm)〕
- Super line filter LSF series 〔Removes solid substance (above 1μm)〕
- Super mist filter MSF series 〔Removes solid substance and oil (above 0.01μm)〕
- Super carbon filter KSF series 〔Removes oil and odour (Outlet oil concentration 0.003wtppm)〕
Specifications
DSF-AL/ LSF-AL/ MSF-AL/ KSF-AL Series
Model | DSF/LSF/MSF | 75-AL | 150-AL | 200-AL | 250-AL | 400-AL | |
KSF | — | ||||||
Air processing capacity*1 | Pressure 0.69MPa | m3 /min | 0.35 | 1.2 | 1.8 | 2.7 | 3.9 |
Casing material |
Aluminum diecasting (All AL-Filter are alumite-treated on the inside surface) |
||||||
Operating range | Fliud/Inlet air pressure | MPa | Compressed air/0.05 – 1.0 | ||||
Inlet air temperature | ℃ | 5~60 | |||||
Ambient temperature | ℃ | 2~60 | |||||
Performance*2 | Filtration | DSF:5μm (water droplet separation efficiency 99%), LSF:1μm (collecting performance 99.999%), MSF:0.01μm (collecting performance 99.999%), KSF:Absorption by activated carbon fibre |
|||||
Outlet oil concentration | wt ppm | MSF: 0.01, KSF: 0.003 | |||||
Pressure Loss | MPa | DSF: Initial 0.005, LSF: Initial 0.005, MSF: Initial 0.01 / Normal 0.02, KSF: Initial 0.009 | |||||
When to replace filter element*3 | 1 year, or DSF:0.02MPa, LSF/MSF: 0.035MPa, whichever comes first | ||||||
Connections | Pipe connections | Rc 3/8 | Rc1/2 | Rc3/4 | Rc1 | ||
Different pressure gauge conditions | Rc1/4 | ||||||
Mass | kg | 1.0 | 2.0 | 2.1 | 2.6 | ||
Filter | Model: ELS/EMS EKS/EDS |
75 | 150 | 200 | 250 | 400 | |
Unit(s) used | unit(s) | 1 | |||||
Accessories | Auto drain trap*4 | LSF/ MSF/ DSF | NH503-MR (Built-in) | ||||
Differential pressure gauge | Option | DG-50(A) (Comes along LSF and MSF. Optional for DSF and KSF) |
Model | DSF/LSF/MSF | 700-AL | 1000-AL | 1300-AL1 | 2000-AL1 | |
KSF | 1300-AL | 2000-AL | ||||
Air processing capacity*1 | Pressure 0.69MPa | m3 /min | 6.6 | 10.6 | 13.8 | 20 |
Casing material |
Aluminum diecasting (All AL-Filter are alumite-treated on the inside surface) |
|||||
Operating range | Fliud/Inlet air pressure | MPa | Compressed air/0.05 – 1.0 | Compressed air/0.1 – 1.0(KSF: 0.05〜1.0) | ||
Inlet air temperature | ℃ | 5~60 | ||||
Ambient temperature | ℃ | 2~60 | ||||
Performance*2 | Filtration | DSF:5μm (Water droplet separation efficiency 99%), LSF:1μm (Collection efficiency 99.999%), MSF:0.01μm (Collection efficiency 99.999%), KSF: Absorption by activated carbon fibre |
||||
Outlet oil concentration | wt ppm | MSF:0.01, KSF:0.003 | ||||
Pressure Loss | MPa | DSF: Initial 0.005, LSF: Initial 0.005, MSF: Initial 0.01 / Normal 0.02, KSF: Initial 0.009 | ||||
When to replace filter element*3 | 1 year, or DSF:0.02MPa, LSF/MSF: 0.035MPa, whichever comes first | |||||
Connections | Pipe connections | Rc1 1/2 | Rc2 | |||
Different pressure gauge conditions | Rc1/4 | |||||
Mass | kg | 5 | 6 | 6.5 | 9 | |
Filter | Model: ELS/EMS EKS/EDS |
700 | 1000 | 1300 | 2000 | |
Unit(s) used | unit(s) | 1 | ||||
Accessories | Auto drain trap*4 | LSF/ MSF/ DSF | NH503-MR (Built-in) | FD2 | ||
Differential pressure gauge | DG-50(A) (Comes along LSF and MSF. Optional for DSF and KSF) |
*1 Air Processing Capacity is converted to the suction air condition. (Ambient pressure, 32℃, 75%)
*2 Air Processing Capacity: Inlet air pressure 0.69, inlet air temperature 32℃, inlet air dew point – 17℃ (10℃ under pressure) (MSF,KSF),
inlet oil concentration 3wt ppm (LSF/MSF) / 0.01wt ppm (KSF).
*3 Replace either at the end of use period or when the pressure drops, whichever comes first. Replacement timing provided is not a guaranteed value.
Replacement may be required before the provided replacement timing, as it depends on the product environment, operating condition, etc.
*4 All auto drain traps are float type only.
*Please be sure to install the air dryer in front of the MSF series.
*Please be sure to install the air dryer, LSF and MSF in front of the KSF series.
*The elements is not attached to the housing at the time of shipment. After installing the hosing and flushing, use the attached element.
Please install according to the operating manual.